How High-Capacity Reverse Osmosis Plants Improve Industrial Water Treatment Efficiency

Manufacturing and processing facilities need a steady supply of treated water to keep production running. When feed water contains high concentrations of dissolved salts and minerals, the treatment system must deliver the required water quality while making efficient use of the incoming supply.

At Orient Energy Systems (OES), we recently engineered, installed and commissioned a reverse osmosis (RO) plant for Selimpex International. The plant was designed around the facility’s feed water quality, treated water demand and recovery requirements.

Selimpex International Project Specifications

Parameter

Specification

Plant capacity

75,000 gallons per day (GPD)

Feed water total dissolved solids (TDS)

8,000 ppm

System recovery

70%

How Reverse Osmosis Treats High-TDS Feed Water

Reverse osmosis uses pressure to push water through semipermeable membranes. The membranes allow water to pass through while rejecting a large share of the dissolved salts and minerals. The treated water is called permeate. The remaining stream, known as concentrate or brine, carries away the rejected dissolved solids.

Industrial and commercial facilities can use RO to treat high-TDS water sources when their operations require water with a lower concentration of dissolved solids.

What 70% System Recovery Means

System recovery measures the percentage of feed water converted into permeate. At 70% recovery, the Selimpex plant produces about 70 gallons of treated water for every 100 gallons of feed water under the specified operating conditions. The other 30 gallons leave the system as concentrate.

For the same volume of treated water, higher recovery can reduce the amount of feed water needed and the volume of concentrate produced. As recovery increases, the rejected salts become more concentrated in the remaining water. This can increase the risk of scaling, so the recovery target must account for the feed water chemistry, membrane performance and how the facility will manage the concentrate.

How OES Designs Industrial RO Plants Around Site Requirements

Feed water composition, treated water demand and available infrastructure vary from one facility to another. Those inputs guide the project from initial design through commissioning.

  1. Analyse the feed water. Measure TDS and assess the water’s composition to identify minerals and other constituents that could cause scaling or foul the membranes.
  2. Define the treated water requirements. Establish the volume and quality of permeate the facility needs and set a recovery target suited to the feed water and operating conditions.
  3. Design the treatment system. Select the pretreatment, membranes, operating pressure and system controls to meet the treatment requirements and support reliable operation.
  4. Install and commission the plant. Integrate the equipment with the facility’s infrastructure and verify that it operates according to its design parameters.

Supporting Efficient Industrial Water Management

Where the water source and intended use are suitable, reverse osmosis can support water reuse and reduce reliance on freshwater supplies. Long-term efficiency also depends on the energy needed to operate the plant, regular maintenance and responsible concentrate management.

OES provides customised water treatment solutions for industrial facilities that need to treat high-TDS feed water or use their existing water supply more efficiently.